Here are five things to know from the study:
- Before the intervention, the department’s peak turnaround time for mammogram reports reached 198 hours, or 8.25 days.
- Researchers identified three causes for the delayed reporting: radiologist interruptions, a paper-based workflow and a “cumbersome” dictation process.
- To address these issues, the team implemented a batched, uninterrupted and digitized workflow for radiologists to follow, and set an institutional turnaround time goal of 72 hours, or three days.
- Radiologists reported their distraction decreased from 5.6 points to 2.0 points and their fatigue decreased from 4.8 points to 2.6 points, with the new workflow.
- The average daily volume of mammogram interpretation increased from 21.0 to 50.3.
The department met its 72-hour goal 14 of the 15 week-long intervention study period, compared to six of the initial 17-week pre-intervention study period.
Read the full study here.
At the Becker's 11th Annual IT + Revenue Cycle Conference: The Future of AI & Digital Health, taking place September 14–17 in Chicago, healthcare executives and digital leaders from across the country will come together to explore how AI, interoperability, cybersecurity, and revenue cycle innovation are transforming care delivery, strengthening financial performance, and driving the next era of digital health. Apply for complimentary registration now.